MORTH ORANGE BOOK SEC-700 GEO SYNTHETICS TABLES -CIVIL ENGINEERS GEO TEXTILES REFFERENCEE


MORTH (MINISTRY OF ROAD TRANSPORT AND HIGHWAY)
TABLES FOR GEOSYNTHETICS
SECTION : 700 , MORTH REV : 5 , YEAR 2013

Table 700-1:  Minimum Geotextile Strength Property Requirements

Installation Condition
Type
Strength Property Requirement (MARV)
Grab Strength in Newton  (N) as per ASTM D 4632/IS:13162 Part 5
Tear Strength in Newton (N) as per ASTM Newton (N) D 4533/IS:14293 Part 4
Puncture Strength  in Newton  (N) as Per IS:13162 IS:1
Burst Strength in as per ASTM D 3786/966
Elongation at Failure

LT50%
MT50%
LT50 %
MT50%
LT50%
MT50%
LT50%
MT50%
Harsh installation condition
Type 1
1400
900
500
350
500
350
3500
1700
Moderate Installation condition
Type II
1100
700
400
250
400
250
2700
1300
Less Severe Installation condition
Type Ill
800
500
300
180
300
180
2100
950